Mts Series 505G2 SilentFlo Hydraulic Power Unit Model Manuale Utente

Navigare online o scaricare Manuale Utente per Hardware Mts Series 505G2 SilentFlo Hydraulic Power Unit Model . MTS Series 505G2 SilentFlo Hydraulic Power Unit Model 505G2-11 User Manual Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa

Sommario

Pagina 1 - Product Information

be certain.mModel 505G2.07Model 505G2.11Series 505G2 SilentFlo™ Hydraulic Power UnitProduct Information100-227-350 C

Pagina 2 - Publication information

Model 505G2.07/.11 SilentFlo™ HPU10ConventionsConventionsDocumentation ConventionsThe following paragraphs describe some of the conventions that are u

Pagina 3 - Contents

Documentation ConventionsModel 505G2.07/.11 SilentFlo™ HPU11Hypertext links The electronic document has many hypertext links displayed in a blue font.

Pagina 4 - Accessories 63

Model 505G2.07/.11 SilentFlo™ HPU12Documentation Conventions

Pagina 5 - Technical Support

EU DeclarationsModel 505G2.07/.11 SilentFlo™ HPU13IntroductionThe MTS Model 505.07 Hydraulic Power Unit (HPU) and Model 505.11 HPU provide high-pressu

Pagina 6 - Before You Contact MTS

Model 505G2.07/.11 SilentFlo™ HPU14Product Information CDProduct Information CDA Product Information CD is supplied with the HPU (MTS part number 100-

Pagina 7 - If You Contact MTS by Phone

Component IdentificationModel 505G2.07/.11 SilentFlo™ HPU15Component IdentificationComponent Descriptions (part 1 of 2)Item Component Description1 Ou

Pagina 8

Model 505G2.07/.11 SilentFlo™ HPU16Component Identification9 ReservoirHolds the hydraulic fluid and houses the hydraulic pump and motor. The surge sup

Pagina 9 - Before You Begin

Functional DescriptionModel 505G2.07/.11 SilentFlo™ HPU17Functional DescriptionPump A variable volume pump draws hydraulic fluid from the reservoir an

Pagina 10 - Conventions

Model 505G2.07/.11 SilentFlo™ HPU18Auto-Cooling Valve (adjustable)Auto-Cooling Valve (adjustable)The auto-cooling function is integrated into the cont

Pagina 11 - Documentation Conventions

General Safety Practices: Hydraulic Power Units andModel 505G2.07/.11 SilentFlo™ HPU19SafetyGeneral Safety Practices: Hydraulic Power Units and Hydrau

Pagina 12

Copyright information © 2013 MTS Systems Corporation. All rights reserved.Trademark information MTS and SilentFlo are registered trademarks of MTS Sys

Pagina 13 - Introduction

Model 505G2.07/.11 SilentFlo™ HPU20General Safety Practices: Hydraulic Power Units and It is very important that you study the following safety inform

Pagina 14 - Product Information CD

General Safety Practices: Hydraulic Power Units andModel 505G2.07/.11 SilentFlo™ HPU21Have first aid available Accidents can happen even when you are

Pagina 15 - Component Identification

Model 505G2.07/.11 SilentFlo™ HPU22General Safety Practices: Hydraulic Power Units and Practice goodhousekeepingKeep the floors in the work area clean

Pagina 16

General Safety Practices: Hydraulic Power Units andModel 505G2.07/.11 SilentFlo™ HPU23Handle chemicalssafelyWhenever you use or handle chemicals (for

Pagina 17 - Functional Description

Model 505G2.07/.11 SilentFlo™ HPU24General Safety Practices: Hydraulic Power Units and Know the causes ofunexpected actuatormotionsThe high force and

Pagina 18 - Electrical Control

General Safety Practices: Hydraulic Power Units andModel 505G2.07/.11 SilentFlo™ HPU25Consult MTS when in doubt about the safety or reliability of any

Pagina 19

Model 505G2.07/.11 SilentFlo™ HPU26General Safety Practices: Hydraulic Power Units and Part # 100-223-270Voltage hazard. High voltage exists in the vi

Pagina 20

Install the HPUModel 505G2.07/.11 SilentFlo™ HPU27InstallationThis section describes how to install the Series 505 Hydraulic Power Unit (HPU).Note The

Pagina 21

Model 505G2.07/.11 SilentFlo™ HPU28Install the HPUB. Connect the grounding wire to the lug labeled PE GND (protective earth ground).3. Connect the hyd

Pagina 22

Install the HPUModel 505G2.07/.11 SilentFlo™ HPU29Note For hydraulic connections to air-cooled units, refer to the Air-Cooler to SilentFlo™ HPU Integr

Pagina 23

Model 505G2.07/.11 SilentFlo™ HPU Contents3ContentsTechnical Support 5How to Get Technical Support 5Before You Contact MTS 5If You Contact MT

Pagina 24

Model 505G2.07/.11 SilentFlo™ HPU30HPU SetupD. Verify the motor rotation (the pump motor can start with the wrong rotation). Press the High Pressure s

Pagina 25

HPU SetupModel 505G2.07/.11 SilentFlo™ HPU313. On the user interface Main screen ensure that the Remote Operation button is not selected (gray), indic

Pagina 26

Model 505G2.07/.11 SilentFlo™ HPU32HPU Setup5. The following table describes the pushbuttons and indicators on the Setup screen.Name and Location Desc

Pagina 27 - Installation

HPU SetupModel 505G2.07/.11 SilentFlo™ HPU33Mean Temp/numeric display and Deadband/numeric displayPart of the Analog Option;only displayed if the Anal

Pagina 28

Model 505G2.07/.11 SilentFlo™ HPU34HPU Setup

Pagina 29

Model 505G2.07/.11 SilentFlo™ HPU35OperationThis section describes the front panel controls and indicators, and provides operating instructions for th

Pagina 30 - HPU Setup

Model 505G2.07/.11 SilentFlo™ HPU36Operator’s PanelOperator’s PanelMain ScreenThe Main screen is displayed initially when the HPU is powered up. The f

Pagina 31

Main ScreenModel 505G2.07/.11 SilentFlo™ HPU37Name and Location DescriptionFaulted/Ready/Running/High Pressure/Alarm/Overtemp BypassIndicator. Indicat

Pagina 32

Model 505G2.07/.11 SilentFlo™ HPU38Main ScreenOil Temp(erature)Part of the Analog Option;only displayed if the Analog Option was purchased.Indicator/D

Pagina 33 - °C - black

Status ScreenModel 505G2.07/.11 SilentFlo™ HPU39Status ScreenThe Status screen is displayed by pressing the Status button on the Main screen. The foll

Pagina 34

Model 505G2.07/.11 SilentFlo™ HPU4ContentsOperator’s Panel 36Main Screen 36Status Screen 39Operating the HPU Locally or Remotely 41Recover

Pagina 35 - Operation

Model 505G2.07/.11 SilentFlo™ HPU40Status ScreenOil Level OK/Oil Level FaultIndicator. Used to indicate if the hydraulic fluid level is within accepta

Pagina 36 - Operator’s Panel

Operating the HPU Locally or RemotelyModel 505G2.07/.11 SilentFlo™ HPU41Operating the HPU Locally or RemotelyThe HPU can be operated locally using the

Pagina 37

Model 505G2.07/.11 SilentFlo™ HPU42Recovering from an Interlock2. If not already displayed, press the Main button to display the Main screen.3. Verify

Pagina 38

Changing the Water FlowModel 505G2.07/.11 SilentFlo™ HPU431. Start cooling the hydraulic fluid by circulating hydraulic fluid through the heat exchang

Pagina 39 - Status Screen

Model 505G2.07/.11 SilentFlo™ HPU44Resetting the Thermal Overloads and Circuit BreakersNote When the HPU is turned off, a solenoid valve also shuts of

Pagina 40

Adjusting the Hydraulic PressureModel 505G2.07/.11 SilentFlo™ HPU45Additional protection is provided by circuit breakers. A tripped thermal overload o

Pagina 41

Model 505G2.07/.11 SilentFlo™ HPU46Adjusting the Hydraulic PressurePerform the procedure for adjusting the auto-cooling level if the adjusted output p

Pagina 42 - Recovering from an Interlock

Adjusting the HPU Output Pressure LevelModel 505G2.07/.11 SilentFlo™ HPU47Adjusting the HPU Output Pressure Level1. Turn on high hydraulic pressure. E

Pagina 43 - Changing the Water Flow

Model 505G2.07/.11 SilentFlo™ HPU48Adjusting the Auto-Cooling LevelAdjusting the Auto-Cooling Valve tocorrespond with achange in HPU outputpressurePer

Pagina 44

Adjusting the Auto-Cooling LevelModel 505G2.07/.11 SilentFlo™ HPU495. After the final adjustment tighten the nut to secure the setting.6. Hold the HPU

Pagina 45

How to Get Technical SupportModel 505G2.07/.11 SilentFlo™ HPU5Technical SupportHow to Get Technical SupportStart with yourmanualsThe manuals supplied

Pagina 46

Model 505G2.07/.11 SilentFlo™ HPU50Low/High Pressure Functionality5. If necessary, repeat steps 2 and 3 until the Auto-Cooling Valve is stable and the

Pagina 47

Low/High Pressure FunctionalityModel 505G2.07/.11 SilentFlo™ HPU51A logical progression of fluid conditioning that begins at the HPU is required to mi

Pagina 48 - Cooling Valve to

Model 505G2.07/.11 SilentFlo™ HPU52Low/High Pressure FunctionalityHigh pressure When the Series 505 HPUs are running in high pressure, a considerable

Pagina 49

Model 505G2.07/.11 SilentFlo™ HPU53MaintenanceThis section describes preventive maintenance requirements and their recommended intervals for the HPU.R

Pagina 50

Model 505G2.07/.11 SilentFlo™ HPU54Routine Maintenance Overview ChecklistRoutine Maintenance Overview ChecklistRecommended service to be performed at

Pagina 51

Checking the Hydraulic FluidModel 505G2.07/.11 SilentFlo™ HPU55Checking the Hydraulic FluidHydraulic fluid contamination and deterioration normally oc

Pagina 52 - (2000 psi), consult MTS

Model 505G2.07/.11 SilentFlo™ HPU56Checking the Hydraulic FluidTo avoid these problems, you must maintain a clean hydraulic system. Regularly test sam

Pagina 53 - Maintenance

Replacing the Return Line FilterModel 505G2.07/.11 SilentFlo™ HPU57Replacing the Return Line FilterThe filter element of the HPU should be replaced fo

Pagina 54

Model 505G2.07/.11 SilentFlo™ HPU58Replacing the Return Line Filter6. Wipe out any remaining sludge in the filter housing with a lint-free cloth.7. In

Pagina 55 - Checking the Hydraulic Fluid

Sample the Hydraulic FluidModel 505G2.07/.11 SilentFlo™ HPU59Sample the Hydraulic FluidThis section describes how to check the quality of the hydrauli

Pagina 56

Model 505G2.07/.11 SilentFlo™ HPU6Before You Contact MTSKnow information fromprior technicalassistanceIf you have contacted MTS about this problem bef

Pagina 57

Model 505G2.07/.11 SilentFlo™ HPU60Appearance of Hydraulic Fluid Sample1. Operate the HPU until the hydraulic fluid is at normal operating temperature

Pagina 58

Replacing the Hydraulic FluidModel 505G2.07/.11 SilentFlo™ HPU61Replacing the Hydraulic FluidReplace the hydraulic fluid in the HPU reservoir whenever

Pagina 59 - Sample the Hydraulic Fluid

Model 505G2.07/.11 SilentFlo™ HPU62Replacing the Hydraulic FluidProcedure See “Component Identification” to identify the components called out in the

Pagina 60 - Burnt odor

High Pressure Filter KitModel 505G2.07/.11 SilentFlo™ HPU63AccessoriesContents High Pressure Filter Kit 63Surge Suppressor Kit 65Precharging the

Pagina 61 - Replacing the Hydraulic Fluid

Model 505G2.07/.11 SilentFlo™ HPU64High Pressure Filter Kit3. Connect the elbow to the input of the filter assembly. Connect the straight tube to the

Pagina 62

Surge Suppressor KitModel 505G2.07/.11 SilentFlo™ HPU655. Screw the filter bowl back onto the filter assembly. Torque the filter bowl to 27.1 N•m (20

Pagina 63 - Accessories

Model 505G2.07/.11 SilentFlo™ HPU66Precharging the Surge Suppressor Accumulator1. Ensure that system hydraulic pressure has been reduced to zero befor

Pagina 64 - Replacing the Filter

Precharging the Surge Suppressor AccumulatorModel 505G2.07/.11 SilentFlo™ HPU67Determining apressure checkintervalThe precharge pressure checking inte

Pagina 65 - Surge Suppressor Kit

Model 505G2.07/.11 SilentFlo™ HPU68Precharging the Surge Suppressor Accumulator1. Slowly open the bleed valve on the charging kit until gas begins to

Pagina 66

Lifting KitModel 505G2.07/.11 SilentFlo™ HPU697. Open the locknut. Slowly open the regulator shut-off valve until the pressure indicator on either the

Pagina 67 - 0–21 MPa (0–3000 psi)

If You Contact MTS by PhoneModel 505G2.07/.11 SilentFlo™ HPU7If You Contact MTS by PhoneA Call Center agent registers your call before connecting you

Pagina 68

Model 505G2.07/.11 SilentFlo™ HPU70Lifting KitThe slings and brackets should be positioned as shown.Lifting Support Brackets and SlingsSlingsBracketsB

Pagina 69 - Lifting Kit

Caster KitModel 505G2.07/.11 SilentFlo™ HPU71Caster KitThe caster kit (part number 100-025-327) is a couple of channel supports with casters (two rigi

Pagina 70 - Brackets

Model 505G2.07/.11 SilentFlo™ HPU72Caster Kit

Pagina 71 - Caster Kit

73Appendix A: HPU Maintenance and Service LogsContents 8 Hours/Daily 7440 Hours/Weekly 75160 Hours/Biweekly 76500 Hours 771000 Hours 78

Pagina 72

748 Hours/Daily8 Hours/Daily8 Hours/Daily Service Interval RecommendationCheck Console VerificationCheck Dirty Filter IndicatorsCheck for LeaksCheck o

Pagina 73 - Contents 8 Hours/Daily 74

40 Hours/Weekly7540 Hours/Weekly40 Hours/Weekly Service Interval RecommendationCheck Fluid Color and OdorCheck Interlock DevicesDate Performed by Perf

Pagina 74 - 8 Hours/Daily

76160 Hours/Biweekly160 Hours/Biweekly160 Hours/Monthly Service Interval RecommendationCheck Cables and ConnectorsCheck Console Air FilterDate Perform

Pagina 75 - 40 Hours/Weekly

500 Hours77500 Hours500 Hours Service Interval RecommendationCheck All Accumulators for Proper Precharge Pressure and OilCheck Condition of All Electr

Pagina 76 - 160 Hours/Biweekly

781000 Hours1000 Hours 1000 Hours Service Interval RecommendationAll 500 hr Maintenance ProceduresReplace All FiltersVerify Operation and Settings of

Pagina 77 - 500 Hours

2000 Hours792000 Hours2000 Hours Service Interval RecommendationAll 1000 hr Maintenance ProceduresCheck Pump/Motor Coupling for Wear and DebrisCheck P

Pagina 78 - 1000 Hours

Model 505G2.07/.11 SilentFlo™ HPU8Problem Submittal Form in MTS ManualsProblem Submittal Form in MTS ManualsUse the Problem Submittal Form to communic

Pagina 79 - 2000 Hours

805000 Hours5000 Hours5000 Hours Service Interval RecommendationRecommend R/R Heat ExchangerDate Performed by Notes

Pagina 80 - 5000 Hours

10,000 Hours8110,000 Hours10,000 Hours Service Interval RecommendationRecommend R/R Heat ExchangerRecommend Replacement of HosesInspect Motor Bearings

Pagina 85

mMTS Systems Corporation14000 Technology DriveEden Prairie, Minnesota 55344-2290 USAToll Free Phone: 800-328-2255(within the U.S. or Canada)Phone: 952

Pagina 86

Before You BeginModel 505G2.07/.11 SilentFlo™ HPU9PrefaceBefore You BeginSafety first! Before you use your MTS product or system, read and understand

Commenti su questo manuale