MTS TestSuite™ Fracture Analyzer User Guide
100-219-118 E be certain.
Vedere la pagina 0
1 2 3 4 5 6 ... 95 96

Sommario

Pagina 1 - 100-219-118 E be certain

MTS TestSuite™ Fracture Analyzer User Guide100-219-118 E be certain.

Pagina 2

• Write down any specific instructions.After you callMTS logs and tracks all calls to ensure that you receive assistance for your problem or request.

Pagina 3 - Contents

2.0 Preface2.1.0 Before You BeginSafety first!Before you use your MTS product or system, read and understand the safety information provided with your

Pagina 4 - 6.0 Data Analysis 53

CAUTION:Caution notices indicate the presence of a hazard with a low level of risk which, ifignored, could cause moderate or minor personal injury or

Pagina 5 - 7.0 Variable Analysis 61

Hypertext linksThe electronic document has many hypertext links displayed in a blue font. All blue words in the body text,along with all contents entr

Pagina 7 - 1.0 Technical Support

3.0 IntroductionTopics:•Application Overview...

Pagina 8

3.1.0 Application OverviewThis application enables standard and custom in-depth analysis of test data, including post-processing, usingbasic statistic

Pagina 9

DescriptionIconNameA test is the core component of MTS TestSuite. The test contains the testdefinition along with any test runs, analysis definitions,

Pagina 10

A Project Contains Project Settings, Tests, and Test Templates3.2.2.0 TestA Test is stored within a project folder, and contains the following compone

Pagina 11 - 2.0 Preface

A Test Contains the Test Definition, Test Run(s), Analysis Definition(s), and Analysis Run(s)3.2.3.0 Test DefinitionThe test definition is stored with

Pagina 12

© 2013 MTS Systems Corporation. All rights reserved.Trademark InformationMTS is a registered trademark of MTS Systems Corporation within the United St

Pagina 13 - Hypertext links

of the test. After a test run is complete, values that are stored in variables can be changed using theFatigue Analyzer and the Fracture Analyzer in o

Pagina 14

Components of a Test RunMTS TestSuite™ Fracture Analyzer User Guide 213.0 Introduction

Pagina 15 - 3.0 Introduction

3.2.5.0 Test Run State ColorsThe color of a test run entry indicates its run state.Test Run State ColorsDescriptionColorThe test run completed success

Pagina 16 - 3.1.0 Application Overview

An Analysis Definition Contains Views, Displays, Variables, DAQ Mappings, and Functions3.2.7.0 Analysis RunsAnalysis runs apply the views and variable

Pagina 17 - 3.2.1.0 Project

Analysis Runs use the Analysis Definition and Test Run Data to Generate Data3.3.0 Viewing the Main WindowThe Fracture Analyzer application main window

Pagina 18 - 3.2.2.0 Test

DescriptionCalloutError List Panel3Closes Error List and Message Log4Message Log5Work Area63.4.0 Using the Menu Bar3.4.1.0 File Menu OptionsMenus prov

Pagina 19 - 3.2.3.0 Test Definition

DescriptionItem• Test Run—Imports a test run.• Legacy Data—Retrieves test runs, templates or files from data archivedfrom previous software products.

Pagina 20 - 3.2.4.0 Test Run

View Menu OptionsDescriptionItemReturns all views to a docked position.Re-Dock All ViewsCloses all views in the work area.Close All ViewsAllows you to

Pagina 21 - Components of a Test Run

DescriptionItemShows or removes the Message Log panel. A check mark appears next tothe menu item when the panel is active. To remove or show the panel

Pagina 22 - 3.2.6.0 Analysis Definitions

3.5.0 Using the Analysis ToolbarThe Analysis Toolbar allows you to click an icon to create a new chart or table, manage editors, functions,views, and

Pagina 23 - 3.2.7.0 Analysis Runs

Contents1.0 Technical Support 71.1.0 How to Get Technical Support...

Pagina 24 - 3.3.0 Viewing the Main Window

DescriptionItemUpdate all references to variables, calculation, and data acquisition definitionsusing the current configuration and overridden variabl

Pagina 25 - 3.4.0 Using the Menu Bar

4.0 Getting StartedTopics:•Begin an Analysis...

Pagina 26 - 3.4.3.0 View Menu Options

4.1.0 Begin an AnalysisYou can begin an analysis using a sample test to help you learn the application. If you have a test createdin a testing applica

Pagina 27 - 3.4.4.0 Display Menu Options

4.2.0 Data Analysis4.2.1.0 Activities and TestsAnalysis activities include mathematical and statistical evaluation of the results obtained from the ma

Pagina 29

5.0 Customizing the Main WindowTopics:•Overview...

Pagina 30

5.1.0 Overview5.1.1.0 Understanding Views and DisplaysWithin the application's main window, data is shown in Charts and Tables. Charts and tables

Pagina 31 - 4.0 Getting Started

Four Views Containing Peak-Valley DataWhen you are finished resizing the views to your liking, you can save the current on-screen presentation ofviews

Pagina 32 - 4.1.0 Begin an Analysis

5.1.2.0 Creating, Editing, and Deleting ViewsWhen you create a new view, it is stored in the analysis run. If you delete a view, no change is made to

Pagina 33 - 4.2.0 Data Analysis

Split-Screen DisplayUndocked displaysWhen an undocked display is closed, only the window size is retained. When a display is reopened on adual-screen

Pagina 34

4.2.4.0 Opening an Existing Analysis Run...335.0 Customizing the Main Win

Pagina 35

5.2.0 Configuring Chart and Table Properties5.2.1.0 Populating Charts with DataSome charts, such as the Load vs. Time and Hysteresis charts, allow you

Pagina 36 - 5.1.0 Overview

DescriptionItemAssign an array to the selected trace that is added on the Y axis. Click thedrop-down button for a list of available resource arrays. W

Pagina 37

DescriptionItemSelect the check box to allow a range to automatically expand if the dataexceeds the maximum and minimum ranges. The chart does not res

Pagina 38

5.2.6.0 Limit or Curve Fit Line PropertiesLimit or Curve Fit LinesDescriptionItemClick to add a limit or curve fit line.Add a Limit or CurveFit LineCl

Pagina 39

5.3.0 Charts and Tables (Views)5.3.1.0 Array-Variable ChartThe Array-Variable chart shows data that is collected and calculated during each test cycle

Pagina 40 - 5.2.3.0 Traces Properties

RuntimeIn the Multipurpose Elite application, hysteresis charts are available as part of the Runtime Display andView Results.To create a new Hysteresi

Pagina 41

5.3.4.0 History Marker ChartThe History Marker chart allows you to add markers and lines to history charts. In fatigue tests, you can showfailure cycl

Pagina 42

DescriptionItemShows a panel to set one variable value. The selected marker value appearsin the New Failure Cycle Chart panel. The Value box is unavai

Pagina 43

Cycle Marker Chart PropertiesDescriptionItemSpecify a unique name to identify the chart in the test.Display NameIf more than one type of group is avai

Pagina 44 - 5.3.3.0 Hysteresis Chart

DescriptionItemClick this button to show the Numeric Selection window.NumericClick this button to show the Variables Selection window.Variable5.3.8.0

Pagina 45

6.3.1.0 Multiple Test Runs Overview...576.3.2.0 Analyze Multiple

Pagina 46 - 5.3.4.0 History Marker Chart

5.3.9.0 Variable TableThe Variable table shows the current value of the selected analysis run variables. The table supports directvalue overrides that

Pagina 47 - 5.3.6.0 Cycle Marker Chart

Fixed-Column Boundary Table5.3.11.0 Variable-Column Boundary TableThe Variable-Column Boundary table shows the current values of the selected variable

Pagina 48 - 5.3.7.0 Cycle Time Chart

5.3.13.0 Variable Table for Multiple RunsThe Variable Table for Multiple Runs shows data from two or more analysis runs selected as a multi-runanalysi

Pagina 49 - 5.3.8.0 Array-Variable Table

6.0 Data AnalysisTopics:•Analysis...

Pagina 50 - 5.3.9.0 Variable Table

6.1.0 AnalysisThe application supports a variety of analysis activities, including:• Analysis of completed tests• Reanalysis of a data set requiring u

Pagina 51

specific table. To use a variable in more than one data acquisition activity table, you must map it for eachtable.8. To select the data acquisition ac

Pagina 52

The table row becomes highlighted. The value becomes bold and underlined.Your cursor blinks in thetable cell. A value entry icon appears at the left e

Pagina 53 - 6.0 Data Analysis

6. Select the Is Calculated check box and click ...The Calculation Editor window opens.7. In the Variables panel, select Diameter and right-click Ins

Pagina 54 - 6.1.0 Analysis

6.3.2.0 Analyze Multiple Test RunsWhen the test runs are in your analysis test, open the analysis set and create an analysis run for each testrun. The

Pagina 55 - 6.2.0 Variable Table Analysis

6. Click Update Signal List.7. Click Close to save the changes made in the Data Acquisition Editor.Important:You must click Close before the next step

Pagina 56

7.6.3.0 Mapping Additional Variable Calculations...847.6.4.0 Tagged Blocks...

Pagina 58

7.0 Variable AnalysisTopics:•Variables and Functions...

Pagina 59

7.1.0 Variables and FunctionsYou can analyze test results by reviewing the variables and functions used in the test.You can change thedata presented i

Pagina 60

Variables Editor WindowParts of the Variables Editor WindowDescriptionItemNumberProvides menus and quick-access toolbar icons that allow you to perfor

Pagina 61 - 7.0 Variable Analysis

DescriptionItemNumberFilters by your selected filter criteria and sorts in ascending or descendingorder. If a filter for a column is currently active,

Pagina 62 - 7.2.0 Variables Editor

7.2.3.0 Variable DetailsThe Variable Details panel sets the main properties of the selected variable or variables. New categories aredefined using the

Pagina 63

DescriptionItem• Array of Boolean—The variable holds multiple values of the Boolean datatype.• Array of Numbers—The variable holds multiple values of

Pagina 64 - 7.2.2.0 Variable Categories

DescriptionItemFatigue or Fracture Analysis applications (for example, when a marker ismoved).This check box must be selected if the calculation conta

Pagina 65 - 7.2.4.0 Variable Properties

DescriptionItemIf the value of the variable is not within the range, the application adjusts thevalue to be within the range. If the value of the vari

Pagina 66

• If you delete a variable that uses a local choice list, you also delete the choice list.• If you delete a variable that uses a global choice list, o

Pagina 67

1.0 Technical Support1.1.0 How to Get Technical SupportStart with your manualsThe manuals supplied by MTS provide most of the information you need to

Pagina 68 - 7.2.8.0 Choice Lists

7.3.2.0 Array VariablesArray variables store multiple values of the same data type.You can use array variables in several types ofactivities:• Cycle w

Pagina 69 - 7.3.0 Variable Classes

After you create the new variable in either the Multipurpose Elite, Fatigue Analyzer, or Fracture Analyzerapplications, the Properties panel appears.

Pagina 70 - 7.3.2.0 Array Variables

7.4.0 Managing Variables7.4.1.0 Variables OverviewYou create and define variables on the Variables tab. The application also provides shortcuts in var

Pagina 71 - 7.3.5.0 Calculated Variables

7.4.3.0 Creating a New Variable1. Click the New Variable button.The New Variable window prompts you to type a unique identifier for the new variable.

Pagina 72 - 7.4.0 Managing Variables

To locate where the variable is used, click the entry.• For a calculation, the entry for the calculated variable becomes selected.• For an activity, t

Pagina 73 - 7.4.5.0 Variable Used By

Note:If adjacent variable names are not separated by a space or function in the Calculation panel, they areinterpreted as a single variable name. This

Pagina 74 - 7.5.0 Variable Calculations

Note:Some languages use a semicolon as a list separator instead of a comma. If you are using one of thoselanguages, the last operator of the table wou

Pagina 75

DirectionFunctionOperatorPrecedenceLeft-to-RightBitwise OR|10Left-to-RightLogical AND&&11Left-to-RightLogical OR||12Right-to-LeftAssignment=13

Pagina 76

However, some operators like the Not (!), Ones Complement (~), and Subtraction when used as a Negate(-), operate on only one argument to the right.Fun

Pagina 77 - 7.5.4.0 Calculation Functions

• The function Pi() represents the mathematical constant, pi.• The function SystemRate() represents the system data rate.7.5.6.0 Modulus Calculation F

Pagina 78

Know your site number and system numberThe site number contains your company number and identifies your equipment type (such as material testingor sim

Pagina 79

Cycle ModulusCycleModulus(Stress, Strain[, startIndexLoading, endIndexLoading, startIndexUnloading,endIndexUnloading])CycleModulus returns the average

Pagina 80

StressAStressA(StressMax, StressMin)The StressA function returns the value: ((StressMax - StressMin)/(StressMax + StressMin))StressRStressR(StressMax,

Pagina 81 - 7.6.0 Data Acquisition Editor

Data Acquisition Editor WindowDescriptionCalloutAvailable signals1Other available calculations2Additional variables saved with each cycle or group3Map

Pagina 82 - 7.6.1.0 Variable Mapping

Signal to Variable MappingThe Signal to Variable Mapping part of the window allows you to map signals to variables.Four types of data can be calculate

Pagina 83

• All Variables—Shows all variables, including variables that do not have a calculation.You can changethe variable to include a calculation or change

Pagina 84 - 7.6.4.0 Tagged Blocks

an incomplete pattern indicates a group to investigate. Configure the Hysteresis chart to show you the datafor the groups or cycles of interest.You ca

Pagina 85

7.7.0 Function Manager OverviewThe Function Manager window provides information about the specialized calculations that are used formaterial testing.

Pagina 86

DescriptionItemShow the user-defined type of functions. Functions created in the GeometrySpecimen Editor fall into the Geometry category. Functions cr

Pagina 87 - 7.7.1.0 Edit Function

DescriptionItemthe new name shows in this box.The name is case-sensitive, and must notcontain spaces.Shows the function category. If you create the fu

Pagina 88

Note:The example above is not entered as TestVariableX=10.You must enter SetValue in the FunctionEditor.ArraysTo read a test variable array in a funct

Pagina 89 - 7.7.3.0 Update All

• Keyboard enhancers• Print spoolers• Messaging applications1.3.0 If You Contact MTS by PhoneA Call Center agent registers your call before connecting

Pagina 90

geometry-specific calculations. Placeholders for the common functions are added to the test, if any are notalready there.The body of the function is u

Pagina 91

1. In the Multipurpose Elite application Explorer tab, click Test Definition and click on the Edit button. Inthe Fatigue Analyzer and Fracture Analyze

Pagina 93

IndexAanalysisactivities 33begin 32create definition 22create run 22flow 54runs and sets description 23test run 90without template 32analysis runcompa

Pagina 94

Iimporttest file menu option 25invalid cycle values not plotted 46Llimit line 43line and symbolproperties 42Mmain windowFracture Analyzer application

Commenti su questo manuale