be certain.mModel 242.00Model 242.01Model 242.02Model 242.03Series 242 Actuators Product Information011-562-001 J
Series 242 Actuator Product Information10ConventionsPrefaceConventionsDocumentation ConventionsThe following paragraphs describe some of the conventio
Documentation ConventionsSeries 242 Actuator Product Information Preface11Hypertext links The electronic document has many hypertext links displayed i
Series 242 Actuator Product Information12Documentation ConventionsPreface
Series 242 Actuator Product Information Introduction13IntroductionThe Series 242 Actuator is a linear actuator. A linear actuator is a hydraulically p
Series 242 Actuator Product Information14Introduction• Low force structural fatigue• High velocity, short stroke component tests• Low friction, low si
Series 242 Actuator Component IdentificationSeries 242 Actuator Product Information Introduction15Series 242 Actuator Component IdentificationSeries 2
Series 242 Actuator Product Information16Series 242 Actuator Component IdentificationIntroductionSeries 242 Actuator Component DescriptionsCOMPONENT D
242 Actuator Functional DescriptionSeries 242 Actuator Product Information Introduction17242 Actuator Functional DescriptionA linear actuator is used
Series 242 Actuator Product Information18242 Actuator LVDT OperationIntroduction242 Actuator LVDT OperationThe internally mounted LVDT provides an ind
242 Actuator Force SpecificationsSeries 242 Actuator Product Information Introduction19242 Actuator Force Specifications242 Actuator DimensionsActuato
Manual Template 4.32Copyright information © 1985, 1987, 1989–1991, 1993, 2000, 2008 MTS Systems Corporation. All rights reserved.Trademark information
Series 242 Actuator Product Information20242 Actuator DimensionsIntroduction76.2 mm(3.0 in) sq.1/2 - 20 UNF-2B x 1.0 in(25.4 mm)1/2 - 20 UNF-2B x 3.62
Hazard Placard PlacementSeries 242 Actuator Product Information Safety Information21Safety InformationHazard Placard PlacementHazard placards contain
Series 242 Actuator Product Information22Hazard Placard PlacementSafety InformationPart # 045-283-501CAUTIONHigh drain pressure can cause rod seal dam
Hazard Placard PlacementSeries 242 Actuator Product Information Safety Information23Part # 037-588-801Hydraulic Actuator ID tag lists the following:•
Series 242 Actuator Product Information24Hazard Placard PlacementSafety Information
Load Unit ConfigurationSeries 242 Actuator Product Information Installation25InstallationInstalling the Series 242 Actuator depends on the testing app
Series 242 Actuator Product Information26Installing a Fixture to the ActuatorInstallationSee the system assembly drawing, system functional drawing, a
Installing a Fixture to the ActuatorSeries 242 Actuator Product Information Installation27Pedestal Base Mounting HolesThe previous figure shows the th
Series 242 Actuator Product Information28Mounting SwivelsInstallationMounting SwivelsSwivels can be mounted to the piston rod and the pedestal base. A
Connecting the LVDT CableSeries 242 Actuator Product Information Installation29.Connecting the LVDT CableThe following figure shows the electrical con
Series 242 Actuator Product Information3ContentsTechnical Support 5How to Get Technical Support 5Before You Contact MTS 5If You Contact MTS b
Series 242 Actuator Product Information30Connecting Hydraulics-242 ActuatorInstallationConnecting Hydraulics-242 ActuatorHydraulic connections to the
Series 242 Actuator Product Information Operation31OperationThis section describes the operation of the Series 242 Actuator and the internally mounted
Series 242 Actuator Product Information32242 Actuator Operating ConsiderationsOperation242 Actuator Operating ConsiderationsPiston rod banding Piston
Sideload Calculation ProcedureSeries 242 Actuator Product Information Operation33• Minimum allowable sideload frequencySideload Calculation ProcedureT
Series 242 Actuator Product Information34Sideload Calculation ProcedureOperationwhere:S = Actuator stroke (see table)A = Actuator bearing spacing (see
Sideload Calculation ProcedureSeries 242 Actuator Product Information Operation35Use the following equation:Minimum Sideload Frequency K L× 0.01×=
Series 242 Actuator Product Information36Sideload Calculation ProcedureOperation
242 Actuator Maintenance ScheduleSeries 242 Actuator Product Information Maintenance37MaintenanceThe Series 242 Actuator is designed for extended peri
Series 242 Actuator Product Information38242 Actuator Maintenance ScheduleMaintenance
Series 242 Actuator Product Information4Operation 31242 Actuator Operating Considerations 32Sideload Calculation Procedure 33Maintenance 3
mMTS Systems Corporation 14000 Technology Drive Eden Prairie, Minnesota 55344-2290 USA Toll Free Phone: 800-328-2255 (within the U.S. or Canada) Phone
How to Get Technical SupportSeries 242 Actuator Product Information Technical Support5Technical SupportHow to Get Technical SupportStart with yourmanu
Series 242 Actuator Product Information6If You Contact MTS by PhoneTechnical SupportKnow information fromprior technicalassistanceIf you have contacte
Problem Submittal Form in MTS ManualsSeries 242 Actuator Product Information Technical Support7If you are calling about an issue that has already been
Series 242 Actuator Product Information8Problem Submittal Form in MTS ManualsTechnical Support
Before You BeginSeries 242 Actuator Product Information Preface9PrefaceBefore You BeginSafety first! Before you attempt to use your MTS product or sys