DimensionItem
M6 X 1.0 mm -6H 11.98 mm deep (0.472 deep) Four placesJ
31.41 mm (1.237 in) Two placesK
62.86 mm (2.475 in) Two placesL
Loadcell Fixture Mounting Dimensions
This section defines the loadcell's fixturing interface. The system loadcell can be mounted to either the
baseplate, or the crosshead. The graphic in this section and the sections above show the loadcell mounted
to the crosshead.
Loadcell Fixture Mounting Dimensions
DimensionItem
16.012 mm +0.0254 mm -.00000 mm (0.6304 in +0.0010 -0.0000 in)A
1.54 mm (0.060 in) x 45°B
R. 0.76 mm (R. 0.030 in) MaximumC
11.98 mm (.472 in) Thread depthD
18.33 mm (0.722 in) Total depthE
6.35 mm (0.250 in)F
M6 X 1.0 mm -6H 11.98 mm deep (0.472 in deep)G
25.14 mm (0.99 in)H
Keep fixturing below this lineI
3.81 mm (0.15 in)J
44 MTS Acumen™ Electrodynamic Test System
Installation
Vedere la pagina 43