Models FlexTest® IIm/GT/SE Controller Hardware
Emergency Stop Connections
FlexTest GT Controller Connections
130
J24 E-STOP In is a 15 pin type D female connector.
15-contact type D male EMI connector.
Backshell–EMI metallized plastic.
Cable–24 AWG 4 connector with overall foil shield, (Belden 9534 or
equivalent) with drain wire connected to metallized plastic backshell at the
chassis and to ground at the emergency stop station.
Jumper plug required If connector J24 is not used, you must install a jumper plug to maintain the
integrity of the interlocks. Use jumper plug PN 039-713-201 or jumper pins: 5
and 7; 8 and 13.